精品一区二区三区在线观看视频,亚洲人成亚洲人成在线观看,国产成人无码午夜视频在线观看 ,色婷婷AV一区二区三区之红樱桃

當(dāng)前位置:首頁 > 翻譯學(xué)習(xí)

醫(yī)用CO2儀器開機(jī)提示-中英版

發(fā)布時(shí)間:2014-7-26      閱讀次數(shù):1196

醫(yī)用CO2儀器開機(jī)提示-中英版
Startup presentation
1) 在操作本儀器前應(yīng)詳細(xì)閱讀使用說明書,并嚴(yán)格按操作程序操作。
1) Please read this instruction carefully before operating this instrument and perform strictly according to operation procedure.
2)只允許使用醫(yī)用CO2氣體和食用CO2氣體,嚴(yán)禁使用工業(yè)級CO2氣體.
2) Only medical grade C02 gas and edible C02 gas are available, and industrial level C02 gas is strictly prohibited.
3)請先打開電源開關(guān),開機(jī)后再插入輸氣管。若中途斷電需重新開機(jī)時(shí),應(yīng)先拔下輸氣管,上電開機(jī)后再插入。
3) Please switch on the power supply firstly, and insert air pipe after startup of machine. If electricity failures in the half-way and needs restart, please draw air pipe and then re-insert it after startup.
郵編:200437
Post Code: 200437
電話:086-021-65555696 
Tel: 086-021-65555696
傳真:086-021-65557095
Fax: 086-021-65557095
一. 基本參數(shù)
I. Basic Parameters
1)控壓范圍:0~24mmHg;0~30Kpa
1) Range of Pressure Control: 0~24mmHg; 0~30Kpa
2)最大充氣流量:30L/min
2) Maximum Gas Loading Flux: 30L/min  
3)輸入氣源:0.3Mpa±0.1Mpa             
3) Inputting Air Source: 0.3Mpa±0.1Mpa
4)電源電壓:AC220V±22V 50Hz±1Hz 
4) Voltage of Electric Power: AC220V±22V 50Hz±1Hz
5)輸入功率:≤200VA
5) Input Power ≤200VA
6)熔絲管:FUSE-F-2A Φ5X20 mm
6) Fuse Tube: FUSE-F-2A Φ5X20 mm
二. 主要用途
II. Main Purpose
HPQK-A-30L智能化大流量氣腹機(jī)在婦科外科等進(jìn)行腔鏡手術(shù)診治時(shí)作CO2氣體 充氣起腹及皮下充氣之用。
HPQK-A-30L Interlligentized insufflator with large flux has functions of infusing CO2 for abdomen and sub-skin on operation of laparoscopy on gynecology and surgery.
三.設(shè)備特點(diǎn)
III. Equipment Specialty
1)以觸摸液晶屏為媒體,具有友好的人機(jī)界面。
1) Take touch-screen of liquid crystal as media with friendly man-machine interface.
2)以操作者設(shè)定的氣壓、流量值為限,實(shí)行智能化連續(xù)閉環(huán)監(jiān)測調(diào)控。
2) Advanced servo loop technology for air-pressure and flow value control.
3)系統(tǒng)動(dòng)態(tài)反應(yīng)速度快,壓力控制精度高。
3) System has quick dynamic response, and pressure control has high precision.
4)具有智能適應(yīng)外接器件通徑流量的功能
4) Has the intellectual function of fitting external connecting device
5)采用雙傳感器并行檢測技術(shù),確保設(shè)備壓力檢測的安全、穩(wěn)定、可靠。
5) Adopt dual-sensor to inspect technology, and ensure safety, stabilization reliability of equipment pressure. 
6)具有智能報(bào)警和幫助功能,可選擇中文或英文字符顯示。
6) Has intellectual alarm notification and help functions, select display of Chinese or English is available.
7)用戶可選擇以"mmHg"為壓力顯示單位或以"KPa"為壓力顯示單位;同時(shí)還可選擇常規(guī)工作狀態(tài)或氣腹針穿刺狀態(tài)。

7) Pressure unit may be selected as “mmHg” or “KPa”. Meanwhile, routine working status or paracentesis status shall be selected.
8)為確保供氣潔凈干燥,設(shè)備內(nèi)配置高精度自動(dòng)排水過濾裝置。
8) To ensure the air supply is clean and dry, draining and filtering device with a high precision shall be installed in equipment
四.注意事項(xiàng)
IV. Attention Items
五.售后聯(lián)系 
V. After-sale Contact
生產(chǎn)單位:上海匯鵬醫(yī)療設(shè)備有限公司
Production Unit: Shanghai Huipeng Medical Equipment Co., Ltd.
地址:上海市邯鄲路159號上豪大廈12E
Address: E. 12/F, Shanghao Building No. 159# Handan Road, Shanghai
進(jìn)電插座位  
Socket for inputting electricity
進(jìn)氣口        輸氣口
Air intake    Air transmission mouth 
注意:氣源類別:醫(yī)用二氧化碳?xì)怏w  壓力范圍:0.3MPa ±0.1MPa
Notes: sort of air supply: Medical CO2   Pressure Range: 0.3MPa ±0.1MPa
警告:1.請務(wù)必使設(shè)備可靠接地。
Alarm: 1. Please ensure the ground connection of equipment.
2.調(diào)換熔絲管時(shí),務(wù)必切斷電源和拔掉電源進(jìn)電插頭。
      2. If fuse tube needs changing, please make sure that power supply is cut off and the plug contact is pull out in advance
3.拆除中壓輸氣管時(shí),應(yīng)關(guān)閉氣瓶送氣閥,先拆除中壓輸氣管的高壓減壓組件端,再從進(jìn) 氣口氣管接頭處拔下,以防氣體外溢。
3. When dismantle air pipe of medium pressure, valve of air supply of gas cylinder shall be closed; firstly dismantle high-pressure decompression component of medium pressure, then put out from joint of inputting mouth of air pipe avoid air leakage.

2014.7.26